Strona 2 - SAFETY PRECAUTIONS/ WARNINGS

D. CONTINUITY TEST1. Plug the RED test lead into the jack of the multimeter;plug the BLACK test lead into the "COM" jack.2. Set the meter’s

Strona 3

NOTE: To measure current on a particular circuit, you must openup the circuit and connect the test leads in series with the circuitbefore a reading ca

Strona 4 - SPECIFICATIONS

BATTERY AND FUSE REPLACEMENT1. Turn the Digital Multimeter “OFF”and remove the test leads.2. Remove the two screws on the back of the meter and sep-ar

Strona 5

SERVICE PROCEDURESThe Manufacturer warrants to the original purchaser that this unitis free of defects in materials and workmanship under normal usean

Strona 9

Title Page No.INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1SAFETY PRECAUTIONS/WARNINGS . . . . . . . . . . . . .

Strona 10

•DO NOT apply more than the rated voltage, as marked onthe meter, between terminals or between any terminal andearth ground.•Use caution when working

Strona 11

SPECIFICATIONSGENERAL SPECIFICATIONS AND FEATURES•3-½ digit LCD display (maximum reading of 2000); 3 LEDs;green, yellow and red•Auto Range (ACV, DCV,

Strona 12 - MAINTENANCE

AC VOLTSRESISTANCE (OHMS)DC AMPSAC AMPS4Range Resolution Accuracy Notes20.00mA 10µA±(1.0% of Overload Protection: Fusereading 315mA/250V200.0mA 100µA

Strona 13 - SERVICE PROCEDURES

BATTERY TEST (LEDs)DIODE/CONTINUITY TESTS5Function Range Resolution Description NoteDiode Test 2V 1mV Test Current:1±0.6mATest Voltage:OverloadApprox.

Strona 14

CONTROLS AND INDICATORS1. DCV Function: Measures DCvolts. Auto-ranging from 0 to600 volts (10 MΩ impedance)2. ACV Function: Measures ACvolts. Auto-ran

Strona 15

be switched during a test, ALWAYS remove the test leadsfrom the circuit being measured before switching settings.•To avoid possible electric shock, in

Strona 16

1. Plug the RED test lead into the "ΩΩ" jack of the multimeter;plug the BLACK test lead into the "COM" jack.2. Set the meter’s Fun